Process

Specifications
Classifications SFA/AWS A5.1 : E6013
EN ISO 2560-A : E 42 0 RC 11
Approvals ABS : 2
BV : 2
CE : EN 13479
DB : 10.105.06
DNV : 2
LR : 2
UKCA : EN 13479
VdTÜV : 03086

Approvals are based on factory location. Please contact ESAB for more information.

Welding Current AC, DC-(+)
Alloy Type Carbon Manganese
Coating Type Rutile-cellulosic covering
Min AC OCV 50 V
Tensile_Properties
Testing Condition Yield Strength Tensile Strength Elongation
ISO
As Welded 450 MPa 520 MPa 26 %
Tensile_Properties
Testing Condition Yield Strength Tensile Strength Elongation
ISO
As Welded 450 MPa 520 MPa 26 %
Typical Weld Metal Analysis %
C Mn Si
0.07 0.45 0.42
Deposition Data
Diameter Amps Volts Efficiency (Per) Fusion time per electrode at 90Per I max Deposition rate at 90Per
2.5 x 350 mm 60-110 A 23 V 62 % 44 sec 0.9 kg/h
3.2 x 350 mm 90-140 A 24 V 59 % 57 sec 1.1 kg/h
4.0 x 350 mm 110-210 A 26 V 59 % 62 sec 1.5 kg/h
Description Product Number
FILARC 48 2.5x350mm 4772253014
FILARC 48 3.2x350mm 4772323004
FILARC 48 4.0x350mm 4772403004

Fact Sheets

factsheet_icon

FILARC 48

Welding Invented

When our founder Oscar Kjellberg developed the world's first coated welding electrode in 1904, he launched a company whose innovation and uncompromising standards have helped create the history of welding itself. This legacy continues in the quality, performance, and continuous development of the mild steel welding electrodes we make today.

Consistent Performance and Quality, Every Time

Performance is still what sets ESAB covered electrodes apart. No matter the job at hand, with ESAB mild steel and low hydrogen electrodes you are assured of good penetration, consistent mechanical properties, and X-ray quality welds from batch to batch.

Setting the Standard in Covered Electrodes

ESAB covered electrodes exceed industry criteria for low moisture pick up (moisture pick up 0 to 1000°C < 0.4 after 9 hours at 274°C, 80% HR). You can trust ESAB low hydrogen and mild steel electrodes to deliver tough mechanical properties in high or low temperature environments, high humidity worksites, or the most challenging positional welding projects. Plus, their easy-to-use nature make them a simple choice for welders of all skill levels.

Get Expert Support Today

Speak with our team for product details, quotations and service queries.

Chat with us on